The accuracy of a 0-100 mV voltmeter is ±5%. A full-scale reading of 100 mV may be due to a voltage of

The accuracy of a 0-100 mV voltmeter is ±5%. A full-scale reading of 100 mV may be due to a voltage of

Right Answer is:

105 mV or 95 mV

SOLUTION

The limiting error at full scale is

δE = ± 5% of 100

δE = ±5mv

The actual value of limiting error can be expressed as

Ea = Es ± δE

Where

Ea = Actual value

Es = Specified or rated value

δE = Limiting error

Ea = 100 ± 5

Ea = 105 to 95 mV