How much portion of the pole is covered with shading coil or shading band in shaded pole motor?

How much portion of the pole is covered with shading coil or shading band in shaded pole motor?

Right Answer is:

1/3

SOLUTION

A 1/3rd portion of each pole core is surrounded by a copper strip forming a closed-loop called the shading band. When a single-phase AC supply is applied to the stator winding, due to the shading coil provided to the poles, a rotating magnetic field is generated.